CASSETTE TYPES 18-24cas

GRAND STAR


Technical Specifications
:
Indoor
Unit
SAM 024
Outdoor
Unit  “Heat Pump “
CUH 018
CUH 025
Nominal
Cooling Capacity
kW
– Btu/hr
5.28-18000 6.89-23500
Nominal
Heating Capacity
kW
– Btu/hr
5.28-18000 6.89-23500
Cooling
Power Consumption
W
1900
2652
Heating
Power Consumption
W
1500
2575
EER:
Cooling*
Btu/hr.W
9.47
8.86
Heating
*
Btu/hr.W
12.00
9.13
Power
Supply
V/Ph/Hz
220-240/1/50
Air Flow
Rate
(at high speed) Dry coil
m3/hr
710
CFM
420
Dimensions-front
panel (WXHXD)
mm
665X665X30
Dimensions-indoor
unit (WXHXD)
mm
574X574X268
Dimensions-outdoor
unit (WXHXD)
mm
722x586x302
945x649x356
Net
Weight Indoor Unit
kg
23.5
Net
Weight outdoor Unit
kg
44
64.5
Refrigerant
Type
R22

 

Indoor Unit:

cas

– Very elegant design
with ceiling recessed unit except the attractive ceiling
panel that suits any decoration.
– 4 way discharge
louvers provides effective air circulation across the
room eliminating deed zones.
– Energy saving with
low power consumption.
– Ultra quiet
operation.
– Attractive LCD
wireless remote controller with high transmission
ability .
– Decoration pannel
built in display screen indicate operation mode as well
as room temp.
– Advanced-technology
PC-board for full control.
– DRY mode reduce
water vapor by computerized dehumidification .
– SLEEP mode provides
suitable sleeping environment with energy saving .
– Programmable timer
controls the

Automatic timer controls the unit operation .
– Automatic selection
of outlet air direction.
– Automatic selection
of  3-stage indoor fan speed.

-Electronic system provides 3 minutes anti short cycle
protection for compressor , Which guaranties total
system integrity.
Outdoor Unit:

cas 2

–  Fast installation and
easy    maintenance .
– Modern Cabinet design
to suit  the   building decorations.
– Low noise, high
efficiency   compressor .
– Advanced design allows
the use of  either ” Quick Coupling” or ” Flare
“connection systems,for more  flexibility in
installation.
– Heavy gauge galvanized
steel with  weather resistance electrostatic  powder
paint.
– “inner grooved” pipes
and “Slit” fins  increase the heat exchange rate and
decrease power consumption.
– Available as “Cooling
Only” & “Heat   Pump ” systems.
 -Operates in high
outdoor   temperatures.
– Operates in high
outdoor  temperatures.
– Operates in low outdoor
temperatures (heat pump only)
– Optional accessories
available upon  request.
– low -ambient control
kit.
– low – pressure
protection switch.


high-pressure protection switch. 

-crankcase