Grand-Ducted Type دكت

X

DUCTED


DCAM   018-020-024
DCAM 030/036/048/060

ducGRAND STAR

Features:

Very compact design for easy installation above false
ceiling.
Energy saving with low power consumption.
Ultra quiet operation.
Available with Electronic Control using a wired “Touch Pad”

Attractive wireless remote controller with high transmission
ability , or Mechanical control.
Advanced technology PC board for full control.
DRY mode reduces water vapor by computerized
dehumidification.
SLEEP mode provides suitable sleeping environment with
energy saving .
3-stage indoor fan speed.
Electronic system provides 3 minute anti short cycle
protection for compressor , which guaranties total system
integrity.


Technical Specifications
:
Indoor
Unit
DCAM030

DCAM036
DCAM048
DCAM060
Outdoor
Unit  “Heat Pump “
CUH 030** CUHC
036
CUH036*** CUH 050 CUH
060
Nominal
Cooling Capacity
kW
– Btu/hr
 8.79-30000  10.26-35000  10.26-35000  13.19-45000 16.12-55000
Nominal
Heating Capacity
kW
– Btu/hr
 8.79-30000  10.26-35000  10.26-35000  13.77-47000 13.12-44800
Cooling
Power Consumption
W
 3315
4300
3500
5300
6000
Heating
Power Consumption
W
2680
3500
3020
4750
4970
EER:
Cooling*
Btu/hr.W
9.05
8.14
10.00
8.49
9.17
Heating
*
Btu/hr.W
11.19
10.00
11.59
9.89
9.01
Power
Supply
V/Ph/Hz
220-240/1/50
346-380/3/50
Air Flow
Rate
(at high speed) Dry coil
m3/hr
1868
2717
3056
CFM
1100
1600
1800
Dimensions-indoor
unit (WXHXD)
mm
1171X280X527
1314X280X527 1351X350X574 1456X380X574
Dimensions-outdoor
unit (WXHXD)
mm
945X845X356
852X1102X356
Net
Weight Indoor Unit
kg
30
36
41.5
53
Net
Weight outdoor Unit
kg

70
92
82
86
Refrigerant
Type
R22
  At Nominal
ASHRAE rating conditions .
– Cooling :35c
outdoor  DBT / 27 c indoor DBT & 19.5 c indoor WBT.
– Heating::7c
outdoor DBT & 80% relative humidity /20 c indoor DBT.
*
Test volt: 220 for single phase at 50 Hz.
**
This model available with
reciprocating compressor upon request.
***
Rotary compressor.
 Specifications
are subject to change without prior notice.
Very compact
design for easy installation above false ceiling.
 Fast installation
and easy    maintenance .
Energy saving with low power
consumption.
– Modern Cabinet design
to suit  the   building decorations.
Ultra quiet operation. – Low noise, high efficiency
compressor .
Available with Electronic
Control using a wired “Touch Pad”
– Advanced design allows
the use of  either ” Quick Coupling” or ”
Flare  “connection systems,for more  flexibility
in installation.
Attractive wireless remote
controller with high transmission ability , or Mechanical
control.
– Heavy gauge galvanized
steel with  weather resistance electrostatic  powder
paint.
Advanced technology PC board
for full control.
– “inner grooved”
pipes and “Slit” fins  increase the heat exchange
rate and  decrease power consumption.
DRY mode reduces water vapor
by computerized dehumidification.
– Available as “Cooling
Only” & “Heat   Pump ” systems.
SLEEP mode provides suitable
sleeping environment with energy saving .
 -Operates in high outdoor
temperatures.
3-stage indoor fan speed. Operates in low outdoor
temperatures (heat pump only)
Electronic system provides
3 minute anti short cycle protection for compressor , which
guaranties total system integrity.
– Optional accessories available
upon  request.
– Electronic system provides
3 minutes anti short cycle protection for compressor, which
guaranties total system integrity .
– low -ambient control kit.